Good operation of the stenter setting machine

Nov 27, 2022

It should be noted that in order to ensure the good operation of the stenter setting machine, the staff need to regularly lubricate and maintain the width adjustment device, and also carefully check whether the transmission system of the width adjustment device is normal. Normally, the width control system should be tested and adjusted within one month, or adjusted according to the usage of the equipment.

In addition, in the process of operating the stenter setting machine, the operation of the compressed air source also needs to be cautious. First of all, check whether the air pressure of each part is normal, and it should not be lower than the following requirements: traction paddle pressure: 0.35MPa; tension stand: 0.25MPa; two-roll paddle: 0.5MPa; cloth output device: 0.5MPa; Whether it is normal or not, it can work only after meeting the requirements.

In addition to the above operation precautions, the threading cloth operation of the stenter setting machine also needs to be paid attention to. When the cloth is drawn through the traction rolling car, the two-roller rolling car and the overfeeding roller on the cloth feeding frame, care should be taken to avoid the roller from hurting the hands. When the cloth is led through the front cloth storage rack, safety measures also need to be taken to prevent the operator from falling.