After the tenter setting machine has finished processing the cloth, introduce the guide cloth to the operating table, tear the guide cloth, click the general control button of cloth feeding to red, and close the upper needle protection entrance button to "0". Start the second half of the machine, stop when the cloth guide head reaches the cloth overfeeding roller, connect the cloth guide to the guide belt, turn off the tension motor of the cooling cylinder to "0", and start the second half of the machine until the cloth guide completely exits the cloth frame and stops. Turn off the main control button of cloth output to red, and start the machine to let the chain run idly.
Press the oven button to enter the heating system interface, set the heating temperature to 150 degrees, the power of the circulating fan is 50%, and the exhaust fan is manually controlled and exhausted at 100% power, which can effectively remove the remaining moisture in the oven, thereby starting To maintain the role of the oven. Turn off the heating system after running for about 30 minutes, and let the circulating fan and exhaust fan continue to run until the temperature in the oven drops below 100 degrees before turning off. Turn off the main control switch of the power supply of the power-off cabinet to "OFF", the computer will automatically store the processing data and then shut down, and clean the whole machine.
Click the circulation fan schematic icon of the stenter and setting machine to enter the circulation fan power setting window, click the circulation fan total button to pop up the circulation fan power setting small window, click the white number box on the bottom to pop up the numeric keypad, enter the required output power value, Press OK.
Click the icon of the exhaust fan diagram in the upper left corner or the upper right corner of the stenter to enter the exhaust fan power setting window, click the manual control button and confirm, and click the number box on the white background to pop up the small numeric keyboard to enter the required value and confirm. If you click the automatic control button and confirm, the exhaust fan will automatically adjust the power of the exhaust fan.
Click the number box showing the temperature in the oven simulation icon to enter the heating window, click the heating total to set the heating temperature, and you can also set the heating temperature of each section of the oven separately. When the heating temperature is below 90 degrees, click the small fire icon to heat, and when the heating temperature is above 90 degrees, click the large fire icon to heat and confirm.
Start the first half of the machine, after the cloth guide has passed the needle guard entrance, turn on the needle guard entrance button to "1", stop when the cloth guide leaves the oven and reach the cloth discharge overfeed roller, and remove the guide belt from the cloth guide and the cloth discharge part. connected. Click the general control button of the cloth discharge mechanism to green, turn on the motors of the cloth discharge part to "1" (except the tension motor switch of the cooling cylinder), restart the machine, introduce the guide cloth to the cloth discharge rack, and then stop. Turn on the cooling cartridge tension motor switch to "1".
https://www.sunwinmachinery.com/