Cleaning of hot air stenter setting machine

Apr 12, 2022

After the Textile hot air stenter setting machine has finished processing the cloth, introduce the guide cloth to the operating table, tear the guide cloth, click the general control button of cloth feeding to red, and close the upper needle protection entrance button to "0". Start the second half of the machine, stop when the cloth guide head reaches the cloth overfeeding roller, connect the cloth guide to the guide belt, turn off the tension motor of the cooling cylinder to "0", and start the second half of the machine until the cloth guide completely exits the cloth frame and stops. Turn off the main control button of cloth output to red, and start the machine to let the chain run idly.

Press the oven button to enter the heating system interface, set the heating temperature to 150 degrees, the power of the circulating fan is 50%, and the exhaust fan is manually controlled and exhausted at 100% power, which can effectively remove the remaining moisture in the oven, thereby starting To maintain the role of the oven. Turn off the heating system after running for about 30 minutes, and let the circulating fan and exhaust fan continue to run until the temperature in the oven drops below 100 degrees before turning off. Turn off the main control switch of the power supply of the power-off cabinet to "OFF", the computer will automatically store the processing data and then shut down, and clean the whole machine.